Experimental Study on the Installation Process of Electric Heater for Pipeline
Author:
Affiliation:

Beijing Institute of Aerospace Systems Engineering,Beijing 100076

Clc Number:

TK124

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Due to the complexity and non-quantitative process of installation procedure of electric heater for propellant-line,test matrix method according to engineering experience was implemented to determine the influence of the status of insulation flim,glue thickness and embedded air bubble on pipeline heating. This study indicates that by choosing non-overlap wrapping for inner/outer insulation flim and 0.2 mm glue thickness using special rubber scraper, it is useful to reduce air bubble formation and improve the heating quality. The test results may serve as a reference for future installation of similar pipelines with electric heater.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:July 06,2021
  • Revised:September 29,2021
  • Adopted:October 13,2021
  • Online: December 23,2022
  • Published: December 30,2022